Absolute stability

For y′=λyy'=\lambda y, a step of size Δt amplifies a mode by R(z),z=λΔtR(z),\quad z=\lambda\Delta t. The shaded region satisfies ∣R(z)∣≤1|R(z)|\leq1. Its boundary has unit amplification.

Amplification factors and assumptions
Forward Euler
R(z)=1+zR(z)=1+z
Heun (explicit RK2)
R(z)=1+z+z2/2R(z)=1+z+z^2/2
Classical RK4
R(z)=1+z+z2/2+z3/6+z4/24R(z)=1+z+z^2/2+z^3/6+z^4/24
Backward Euler
R(z)=1/(1−z)R(z)=1/(1-z)
Crank–Nicolson
R(z)=(1+z/2)/(1−z/2)R(z)=(1+z/2)/(1-z/2)

This is a scalar or modal test for a linearized system. Check each relevant eigenvalue of the spatial discretization. Non-normal operators can exhibit transient growth even when their eigenvalues satisfy this test.

UC Berkeley notes on absolute stability

Courant and diffusion limits

Check a one-dimensional, constant-coefficient advection–diffusion equation on a uniform grid. This diagram applies to forward Euler with first-order upwind advection and centered second-order diffusion.

C=∣u∣ΔtΔxC=\frac{|u|\Delta t}{\Delta x}
F=DΔt(Δx)2F=\frac{D\Delta t}{(\Delta x)^2}
C+2F≤1C+2F\leq1
Derivation and applicability

For positive velocity, the three coefficients of the update are C+F, 1−C−2F, and F. They are nonnegative and sum to one inside the triangle. The wavenumber at the grid’s Nyquist limit has amplification 1−2C−4F, so outside the triangle its magnitude exceeds one in the Fourier analysis. For negative velocity, the upwind stencil reverses.

The intersections are C ≤ 1 for pure advection and F ≤ 0.5 for pure diffusion. Other spatial schemes, boundary treatments, and multidimensional grids require their own analysis. A stable step can still be too large for the accuracy you need.