Calculators
Turbulence and y⁺
Set k–ω SST inlet values and estimate the wall distance for a target y⁺.
SST inlet values
Convert an inlet speed, turbulence intensity and mixing length into k and ω.
The intensity conversion assumes isotropic inlet velocity fluctuations. The mixing-length relation uses Cμ = 0.09 and provides a boundary-condition estimate. Choose intensity and length from measured or justified inlet conditions.
Wall distance and y⁺
Estimate y⁺ at a known wall distance and solve for a prescribed target y⁺.
Supply a local wall shear magnitude from an estimate, measurement or simulation. The distance is wall-normal and ends at the first cell centre. For a uniform orthogonal first layer with a centred cell, the layer thickness is twice this distance. Choose a target that matches your wall treatment and check the computed y⁺ after solving.